Cable and pipe transits HTM for CHP plants

Price on request
In stock
Request a price
Ask a question
Cable and pipe transits HTM for thermal power plants: sealing of power and control lines in walls and floors, IET fire resistance rating of up to 150 minutes, operating temperature from −60 to +200 °C.

Need consultation?

Our technical specialists will be glad to help you

Ask a question

Description

Description

At thermal power plants, cable routes cross walls and floors in dozens of places, and every such opening must be closed with an assembly that has a rated fire resistance. A cable transit HTM is assembled from a mounting frame and sealing components made of non-combustible elastomer. Transit modules are selected according to the outer diameter of the cable or pipe. A single mounting frame can seal several cables at once — both power and control — or pipes with an outer diameter from 3 to 100 mm.

It is recommended that wiring remain replaceable: the sealing of penetrations should allow cables to be replaced and additional ones laid, and the fire resistance rating of the opening should be no lower than that of the wall or floor. The modular design of transits HTM meets this recommendation directly: unused positions in a section are closed with compensation modules or plug modules made of non-combustible elastomer, while transit modules HTM with a core are fitted as spare capacity. The transit does not lose its properties when a cable is added or removed, and the modules themselves are designed for repeated use.

The IET fire resistance rating reaches 150 minutes, the ingress protection rating is IP66/IP68, and the operating temperature is from −60 to +200 °C in climatic version UHL1 to GOST 15150-69. For the plant's hazardous areas, a version is available with the markings Ex eb I Mc U, Ex eb IIC Gb U, Ex tb IIIC Db U in accordance with TR CU 012/2011.

In HTM-Constructor you can prepare sketches, drawings and specifications for various configurations of cable transits HTM for CHP plants in rectangular and round frames to suit your requirements, and export consolidated project files.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Main types of transits for CHP plants

Rectangular

A modular assembly in a rectangular mounting frame: transit modules, support and retaining plates, HTM-PB or HTM-PBM press-blocks; cables and pipes with an outer diameter of 3 to 100 mm.

Round modular

An HTM-RMK round mounting frame, an HTM-PBK press-block and transit modules; cables and pipes with an outer diameter of 3 to 100 mm.

Reinforced

Frames with increased wall thickness and rounded corners; typically used in shipbuilding.

Round single

A round mounting frame with an HTM-VO press-block for one cable or pipe with an outer diameter of 3 to 508 mm; no transit modules are used.

Threaded single cable transit HTM-VRO

A threaded entry for a single cable with an outer diameter of 3 to 36 mm; installed without welding.

Cabinet

An HTM-RMSH frame for installation in the wall of a metal control cabinet.

Certificates

IET fire resistance rating up to 150 minutes. Operating temperatures from -60°C to +200°C. Compliance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017

Cable and pipe transits HTM are certified for use in explosive atmospheres and carry the explosion protection marking Ex eb I Mc U, Ex eb IIC Gb U, Ex tb IIIC Db U in accordance with TR CU 012/2011

The designs of the main components of the transit — transit modules HTM and HTM-PB or HTM-PBM press-blocks — are patented

Zavod HERMES products are manufactured in Russia and entered in the Register of Russian Industrial Products (Russian Government Decree No. 719 of 17.07.2015) on the basis of an ST-1 certificate of origin

The design of modular transits HTM provides complete protection against dust and the dynamic action of water jets and complies with the ingress protection rating IP66/IP68

The products are certified in accordance with the Technical Regulations of the Customs Union (TR CU / EAEU) and may be used both in the Russian Federation and in Belarus, Armenia, Kyrgyzstan and Kazakhstan

Components of transits HTM are inspected at every stage of production in accordance with the GOST R ISO 9001:2015 (ISO 9001:2015) quality management system

Compliance with the requirements of STO Gazprom 9001-2018 under the INTERGAZCERT voluntary certification system in respect of the manufacture and sale of fire-resistant explosion-proof cable and pipe transits HTM

Fire resistance ratings

A transit HTM prevents fire, smoke and gas from spreading into adjacent rooms. Different levels of fire resistance are achieved through the design features of the installation rather than a separate product range: all transits hold an IET60 certificate. Fire resistance rating — in accordance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017:

Transits in rectangular frames

IET 60

Single rectangular transit.

IET 90

Asymmetric rectangular transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric rectangular transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric rectangular transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

Transits in round frames

IET 60

Single round transit.

IET 90

Asymmetric round transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric round transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric round transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Frequently asked questions

How can I find out the price, availability and delivery times?

Inquiries are sent to the sales department at info@ntm-hermes.com or by phone on +7 (342) 200-88-26. It is worth stating in the inquiry the company and the facility for which the delivery is planned — this speeds up selection and calculation.

Is there a price list for the products?

There is no price list: the cost is calculated individually, depending on the design, materials and scope of supply. First the transit configuration is drawn up, then the managers prepare the calculation.

What does the fire resistance rating of a specific cable or pipe penetration depend on?

The fire resistance rating of the assembly is taken to be no lower than that of the structure through which the cables are routed — a requirement of Federal Law No. 123-FZ (Art. 82, cl. 7). The level is achieved by the installation arrangement and the thickness of the building structure, not by choosing a “more fire-resistant” model: all transits HTM hold an IET60 certificate. Up to 90 minutes — an asymmetrical transit in a structure at least 150 mm thick with a mating frame and PZh120 mineral wool boards; up to 120 minutes — a symmetrical transit in a structure from 150 mm thick with PZh120 boards; up to 150 minutes — a symmetrical transit in a structure from 170 mm thick with PZh120 boards.

What confirms that the transits are suitable for explosion-hazard facilities?

Cable transits HTM are certified for use in explosive atmospheres — a TR CU 012/2011 certificate for use in explosive atmospheres. Explosion protection markings: Ex eb I Mc U; Ex eb IIC Gb U; Ex tb IIIC Db U. Degree of protection against external influences — IP66/IP68.

What is recommended for a cable line sealing assembly?

It is recommended that the sealing where cables pass through walls and floors allow replacement and additional laying of new wires and cables — that is, the penetration is not sealed permanently — and that the fire resistance rating of the opening be no lower than that of the wall or floor. The modular design of transits HTM remains dismountable: a cable can be replaced or added without destroying the assembly, and positions are reserved in the section for future lines — transit modules HTM with a core are installed instead of blind plugs.

Are transits HTM suitable for cable mezzanines and tunnels?

Yes. A cable mezzanine is a room for laying cables beneath the control boards of power plants and substations; a large number of cable lines pass through its walls and floors, as they do through the walls of cable tunnels. The modular transit HTM makes it possible to seal several cables at once in a single mounting frame, provides a fire resistance rating of up to 150 minutes and prevents fire and smoke from penetrating into adjacent rooms, while the dismountable design allows cables to be replaced and added without destroying the assembly.