Cable and pipe transits HTM for substations, outdoor switchgear, solar and wind power plants: rectangular, round and cabinet mounting frames, ingress protection rating IP66/IP68.

Need consultation?

Our technical specialists will be glad to help you

Ask a question

Description

Description

At power generation, transmission and distribution facilities — solar and wind power plants, energy storage systems, substations and switchgear — cable routes cross building structures all the time. Transits HTM seal such an opening with a modular unit: a transit module consists of a base, a set of inserts and a core, and the inserts are selected to match the outer diameter of the cable and/or pipe, so the insulation is not crushed during tightening.

For the point of penetration, it is recommended that the sealing of the opening allow the replacement and additional laying of new wires and cables, i.e. the penetration is not sealed permanently, and that the fire resistance rating of the opening be no lower than that of the wall or floor. In transits HTM, unused positions in the section are closed with compensation modules or plug modules made of non-combustible elastomer, while positions left for future cabling are fitted with transit modules HTM with a core.

For walls and floors, transits in rectangular and round mounting frames are used; for the wall of a metal control cabinet, transits in HTM-RMSH cabinet mounting frames; all versions provide an ingress protection rating of IP66/IP68. The operating temperature is from −60 to +200 °C with climatic version UHL1 to GOST 15150-69, so the unit can also be used at outdoor switchgear.

In HTM-Constructor you can prepare sketches, drawings and specifications for various configurations of cable transits HTM for the power industry in rectangular and round frames to suit your requirements, and export the consolidated project files.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Main types of transits for power industry facilities

Rectangular

A modular assembly in a rectangular mounting frame: transit modules, support and retaining plates, HTM-PB or HTM-PBM press-blocks; cables and pipes with an outer diameter of 3 to 100 mm.

Round modular

An HTM-RMK round mounting frame, an HTM-PBK press-block and transit modules; cables and pipes with an outer diameter of 3 to 100 mm.

Reinforced

Frames with increased wall thickness and rounded corners; typically used in shipbuilding.

Round single

A round mounting frame with an HTM-VO press-block for one cable or pipe with an outer diameter of 3 to 508 mm; no transit modules are used.

Threaded single cable transit HTM-VRO

A threaded entry for a single cable with an outer diameter of 3 to 36 mm; installed without welding.

Cabinet

An HTM-RMSH frame for installation in the wall of a metal control cabinet.

Certificates

IET fire resistance rating up to 150 minutes. Operating temperatures from -60°C to +200°C. Compliance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017

Cable and pipe transits HTM are certified for use in explosive atmospheres and carry the explosion protection marking Ex eb I Mc U, Ex eb IIC Gb U, Ex tb IIIC Db U in accordance with TR CU 012/2011 

The designs of the main components of the transit — transit modules HTM and HTM-PB or HTM-PBM press-blocks — are patented

Zavod HERMES products are manufactured in Russia and entered in the Register of Russian Industrial Products (Russian Government Decree No. 719 of 17.07.2015) on the basis of an ST-1 certificate of origin

The design of modular transits HTM provides complete protection against dust and the dynamic action of water jets and complies with the ingress protection rating IP66/IP68

The products are certified in accordance with the Technical Regulations of the Customs Union (TR CU / EAEU) and may be used both in the Russian Federation and in Belarus, Armenia, Kyrgyzstan and Kazakhstan

Components of transits HTM are inspected at every stage of production in accordance with the GOST R ISO 9001:2015 (ISO 9001:2015) quality management system

Compliance with the requirements of STO Gazprom 9001-2018 under the INTERGAZCERT voluntary certification system in respect of the manufacture and sale of fire-resistant explosion-proof cable and pipe transits HTM

Fire resistance ratings

A transit HTM prevents fire, smoke and gas from spreading into adjacent rooms. Different levels of fire resistance are achieved through the design features of the installation rather than a separate product range: all transits hold an IET60 certificate. Fire resistance rating — in accordance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017:

Transits in rectangular frames

IET 60

Single rectangular transit.

IET 90

Asymmetric rectangular transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric rectangular transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric rectangular transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

Transits in round frames

IET 60

Single round transit.

IET 90

Asymmetric round transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric round transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric round transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Frequently asked questions

How can I find out the price, availability and delivery times?

Inquiries are sent to the sales department at info@ntm-hermes.com or by phone on +7 (342) 200-88-26. It is worth stating in the inquiry the company and the facility for which the delivery is planned — this speeds up selection and calculation.

Is there a price list for the products?

There is no price list: the cost is calculated individually, depending on the design, materials and scope of supply. First the transit configuration is drawn up, then the managers prepare the calculation.

Will the cable insulation be crushed during sealing?

No. A transit module consists of a base, a set of inserts and a core, and the inserts are selected according to the actual outer diameter of the cable.

How do I seal a cable entry into a switchboard room or control cabinet?

The cable entry is sealed with a modular transit HTM. A mounting frame is installed in the opening: a rectangular or round one for the wall or floor of a switchboard room, an HTM-RMSH cabinet mounting frame for the wall of a metal cabinet. A transit module with inserts matched to the outer diameter is installed on each cable, the module rows are separated by support plates, and the transit is then sealed by tightening the press-block.

What is recommended for a cable line sealing assembly?

It is recommended that the sealing where cables pass through walls and floors allow replacement and additional laying of new wires and cables — that is, the penetration is not sealed permanently — and that the fire resistance rating of the opening be no lower than that of the wall or floor. The modular design of transits HTM remains dismountable: a cable can be replaced or added without destroying the assembly, and positions are reserved in the section for future lines — transit modules HTM with a core are installed instead of blind plugs.

Does the assembly work at unheated infrastructure facilities?

Yes, the operating temperature range is from −60 to +200 °C with climatic version UHL1 according to GOST 15150-69, so the solution can be used both in heated rooms and outdoors.