Ask a question
614513, Russia, Perm Krai, Perm District, Shosse Kosmonavtov 433, bld. 8

Cable and pipe transits HTM for NPPs

Price on request
In stock
Request a price
Ask a question
Cable and pipe transits HTM at nuclear power facilities: sealing of power, instrumentation and control lines, EMC version for instrumentation and control systems, seismic resistance of intensity 9 on the MSK-64 scale.

Need consultation?

Our technical specialists will be glad to help you

Ask a question

Description

Description

At nuclear power facilities, universal modular transits seal the points where power, instrumentation and control cable lines and pipes pass through building structures and prevent fire, smoke, gas and water from spreading into adjacent rooms. A modular design comprising a mounting frame, transit modules and press-blocks does this job with a single assembly rather than a set of separate entries.

Each point where a cable route crosses a wall or floor is treated as a separate element with its own requirements. It is recommended that the wiring remain replaceable and that the sealing allow lines to be replaced and additional lines to be laid, while the fire resistance rating of the opening is taken to be no lower than that of the structure itself (Federal Law No. 123-FZ, Art. 82, cl. 7). In a transit HTM, unused positions in the section are closed with compensation modules or plug modules made of non-combustible elastomer, and transit modules HTM with a core are fitted for spare capacity.

The IET fire resistance rating of transits HTM reaches 150 minutes; the level is determined by the installation scheme, the thickness of the structure and the use of PZh120 mineral wool boards. Ingress protection rating: IP66/IP68. For instrumentation and control system cables, an EMC (electromagnetic compatibility) version is available with a continuous screen of conductive copper foil: it prevents electromagnetic interference and pulses from passing through the transit and earths the braid of the cables passing through. Seismic resistance of intensity 9 on the MSK-64 scale (GOST 30546) and mechanical design groups M25 and M40 to GOST 30631-99 have been confirmed.

In HTM-Constructor you can prepare sketches, drawings and specifications for various configurations of cable transits HTM for NPPs in rectangular and round frames to suit your needs, and export the consolidated project files.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Main types of transits for NPPs

Rectangular

A modular assembly in a rectangular mounting frame: transit modules, support and retaining plates, HTM-PB or HTM-PBM press-blocks; cables and pipes with an outer diameter of 3 to 100 mm.

Round modular

An HTM-RMK round mounting frame, an HTM-PBK press-block and transit modules; cables and pipes with an outer diameter of 3 to 100 mm.

Reinforced

Frames with increased wall thickness and rounded corners; typically used in shipbuilding.

Round single

A round mounting frame with an HTM-VO press-block for one cable or pipe with an outer diameter of 3 to 508 mm; no transit modules are used.

Threaded single cable transit HTM-VRO

A threaded entry for a single cable with an outer diameter of 3 to 36 mm; installed without welding.

Cabinet

An HTM-RMSH frame for installation in the wall of a metal control cabinet.

Certificates

IET fire resistance rating up to 150 minutes. Operating temperatures from -60°C to +200°C. Compliance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017

Cable and pipe transits HTM are certified for use in explosive atmospheres and carry the explosion protection marking Ex eb I Mc U, Ex eb IIC Gb U, Ex tb IIIC Db U in accordance with TR CU 012/2011

The designs of the main components of the transit — transit modules HTM and HTM-PB or HTM-PBM press-blocks — are patented

Zavod HERMES products are manufactured in Russia and entered in the Register of Russian Industrial Products (Russian Government Decree No. 719 of 17.07.2015) on the basis of an ST-1 certificate of origin

The design of modular transits HTM provides complete protection against dust and the dynamic action of water jets and complies with the ingress protection rating IP66/IP68

The products are certified in accordance with the Technical Regulations of the Customs Union (TR CU / EAEU) and may be used both in the Russian Federation and in Belarus, Armenia, Kyrgyzstan and Kazakhstan

Components of transits HTM are inspected at every stage of production in accordance with the GOST R ISO 9001:2015 (ISO 9001:2015) quality management system

Compliance with the requirements of STO Gazprom 9001-2018 under the INTERGAZCERT voluntary certification system in respect of the manufacture and sale of fire-resistant explosion-proof cable and pipe transits HTM

Fire resistance ratings

A transit HTM prevents fire, smoke and gas from spreading into adjacent rooms. Different levels of fire resistance are achieved through the design features of the installation rather than a separate product range: all transits hold an IET60 certificate. Fire resistance rating — in accordance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017:

Transits in rectangular frames

IET 60

Single rectangular transit.

IET 90

Asymmetric rectangular transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric rectangular transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric rectangular transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

Transits in round frames

IET 60

Single round transit.

IET 90

Asymmetric round transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.

IET 120

Symmetric round transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.

IET 150

Symmetric round transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.

HTM-Constructor — free software for calculating and designing modular transits

HTM-Constructor. Free software for calculating
and designing modular transits

Register
HTM-Constructor — free software for calculating and designing modular transits
Register

HTM-Constructor. Free software
for calculating and designing
modular transits

Frequently asked questions

How can I find out the price, availability and delivery times?

Inquiries are sent to the sales department at info@ntm-hermes.com or by phone on +7 (342) 200-88-26. It is worth stating in the inquiry the company and the facility for which the delivery is planned — this speeds up selection and calculation.

Is there a price list for the products?

There is no price list: the cost is calculated individually, depending on the design, materials and scope of supply. First the transit configuration is drawn up, then the managers prepare the calculation.

What does the fire resistance rating of a specific cable or pipe penetration depend on?

The fire resistance rating of the assembly is taken to be no lower than that of the structure through which the cables are routed — a requirement of Federal Law No. 123-FZ (Art. 82, cl. 7). The level is achieved by the installation arrangement and the thickness of the building structure, not by choosing a “more fire-resistant” model: all transits HTM hold an IET60 certificate. Up to 90 minutes — an asymmetrical transit in a structure at least 150 mm thick with a mating frame and PZh120 mineral wool boards; up to 120 minutes — a symmetrical transit in a structure from 150 mm thick with PZh120 boards; up to 150 minutes — a symmetrical transit in a structure from 170 mm thick with PZh120 boards.

Are transits HTM resistant to seismic and vibration loads?

Seismic resistance under loads of up to intensity 9 on the MSK-64 scale and compliance with mechanical design groups M25 and M40 according to GOST 30631-99 have been confirmed. Seismic resistance has been confirmed in the “SeismoBezopasnost” voluntary certification system.

Is there a version with protection against electromagnetic interference?

Yes. Transit modules, press-blocks and single entries are available in the EMC (electromagnetic compatibility) version. Transits in the EMC version are fitted with a continuous screen of conductive copper foil. The screen provides continuous screening of the transit at the point of installation, prevents the passage of electromagnetic interference and pulses, maintains electromagnetic compatibility between electrical and electronic devices, and earths the braid of the cables passing through.

Which cable lines does the transit seal?

Power, control and instrumentation cables, as well as process pipes. The assembly seals the point where they pass through building structures and prevents fire, smoke, gas and water from penetrating into adjacent rooms — with a single modular assembly rather than a set of separate entries.