Need consultation?
Our technical specialists will be glad to help you
Description
In medical laboratories, containment rooms and clinics, a cable entry must simultaneously keep the room sealed and not compromise the fire compartmentation of the building. Modular transits HTM solve this with a single assembly: several cables or pipes — power supply lines and lines of diagnostic and laboratory equipment — can be sealed at once in one mounting frame, while unused positions in the sealing section are closed with compensation modules or plug modules made of non-combustible elastomer.
In the walls and partitions of medical institutions, laboratories and pharmaceutical production facilities, a cable opening is subject to the same rules as at an industrial facility: it is recommended that the wiring remain replaceable and that the sealing allow lines to be replaced and additional ones to be laid, while the fire resistance rating of the opening is taken to be no lower than that of the structure itself (Federal Law No. 123-FZ, Art. 82, cl. 7). For spare capacity, transit modules HTM with a core are installed in the sealing section. The assembly prevents fire and smoke from spreading into adjacent rooms, which is particularly important for escape routes.
The IET fire resistance rating reaches 150 minutes; the level is determined by the installation arrangement and the thickness of the structure. The materials of the sealing elements are classed as hardly combustible (PV-0), have been tested for compliance with group D2 (moderate smoke-generating ability) and group T2 (moderately hazardous in terms of the toxicity of combustion products), have a very faint odor and do not release toxic volatile substances under normal operating conditions. The ingress protection rating is IP66/IP68; for the HTM-RMKS and HTM-RMKF round frames, water-tightness of 6.0 kg/cm² and gas-tightness of 4.0 kg/cm² have been confirmed. For diagnostic equipment, an EMC (electromagnetic compatibility) version is available with a continuous screen of conductive copper foil, which earths the braid of the cables passing through.
Main types of transits for medical laboratories
Rectangular
A modular assembly in a rectangular mounting frame: transit modules, support and retaining plates, HTM-PB or HTM-PBM press-blocks; cables and pipes with an outer diameter of 3 to 100 mm.
Round modular
An HTM-RMK round mounting frame, an HTM-PBK press-block and transit modules; cables and pipes with an outer diameter of 3 to 100 mm.
Reinforced
Frames with increased wall thickness and rounded corners; typically used in shipbuilding.
Round single
A round mounting frame with an HTM-VO press-block for one cable or pipe with an outer diameter of 3 to 508 mm; no transit modules are used.
Threaded single cable transit HTM-VRO
A threaded entry for a single cable with an outer diameter of 3 to 36 mm; installed without welding.
Cabinet
An HTM-RMSH frame for installation in the wall of a metal control cabinet.
Certificates

IET fire resistance rating up to 150 minutes. Operating temperatures from -60°C to +200°C. Compliance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017

Cable and pipe transits HTM are certified for use in explosive atmospheres and carry the explosion protection marking Ex eb I Mc U, Ex eb IIC Gb U, Ex tb IIIC Db U in accordance with TR CU 012/2011

The designs of the main components of the transit — transit modules HTM and HTM-PB or HTM-PBM press-blocks — are patented

Zavod HERMES products are manufactured in Russia and entered in the Register of Russian Industrial Products (Russian Government Decree No. 719 of 17.07.2015) on the basis of an ST-1 certificate of origin

The design of modular transits HTM provides complete protection against dust and the dynamic action of water jets and complies with the ingress protection rating IP66/IP68

The products are certified in accordance with the Technical Regulations of the Customs Union (TR CU / EAEU) and may be used both in the Russian Federation and in Belarus, Armenia, Kyrgyzstan and Kazakhstan

Components of transits HTM are inspected at every stage of production in accordance with the GOST R ISO 9001:2015 (ISO 9001:2015) quality management system

Compliance with the requirements of STO Gazprom 9001-2018 under the INTERGAZCERT voluntary certification system in respect of the manufacture and sale of fire-resistant explosion-proof cable and pipe transits HTM
Fire resistance ratings
A transit HTM prevents fire, smoke and gas from spreading into adjacent rooms. Different levels of fire resistance are achieved through the design features of the installation rather than a separate product range: all transits hold an IET60 certificate. Fire resistance rating — in accordance with the requirements of GOST R 53310-2009 and TR EAEU 043/2017:
Transits in rectangular frames
IET 60
Single rectangular transit.
IET 90
Asymmetric rectangular transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.
IET 120
Symmetric rectangular transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.
IET 150
Symmetric rectangular transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.
Transits in round frames
IET 60
Single round transit.
IET 90
Asymmetric round transit, structure thickness of at least 150 mm, using a mating frame and PZh120 mineral wool boards.
IET 120
Symmetric round transit, structure thickness of at least 150 mm, using PZh120 mineral wool boards.
IET 150
Symmetric round transit, structure thickness of at least 170 mm, using PZh120 mineral wool boards.
Frequently asked questions
How can I find out the price, availability and delivery times?
Inquiries are sent to the sales department at info@ntm-hermes.com or by phone on +7 (342) 200-88-26. It is worth stating in the inquiry the company and the facility for which the delivery is planned — this speeds up selection and calculation.
Is there a price list for the products?
There is no price list: the cost is calculated individually, depending on the design, materials and scope of supply. First the transit configuration is drawn up, then the managers prepare the calculation.
What water- and gas-tightness do transits HTM provide?
The figure depends on the type of mounting frame. Transits in HTM-RMKS and HTM-RMKF round frames: water-tightness 6.0 kg/cm², gas-tightness 4.0 kg/cm². Transits in rectangular thick-walled marine-version frames HTM-RMTS, HTM-RMTSG, HTM-RMTF, HTM-RMTFG: 2.1 and 0.3 kg/cm² respectively. Tests are carried out by air pressurization and water pressure.
Is there a version with protection against electromagnetic interference?
Yes. Transit modules, press-blocks and single entries are available in the EMC (electromagnetic compatibility) version. Transits in the EMC version are fitted with a continuous screen of conductive copper foil. The screen provides continuous screening of the transit at the point of installation, prevents the passage of electromagnetic interference and pulses, maintains electromagnetic compatibility between electrical and electronic devices, and earths the braid of the cables passing through.
Why is not only fire resistance but also the smoke- and gas-tightness of the assembly important for escape routes?
Smoke on escape routes reduces visibility and hinders people from getting out. The transit prevents not only fire but also smoke and gas from penetrating into adjacent rooms.
May transits be used in cleanrooms?
Yes, there is a certificate of approval for use in cleanrooms and associated controlled environments in accordance with GOST 14644. The sealing elements have a very faint odor and do not emit toxic volatile substances under normal operating conditions.